Try Before You Buy

Download a free sample of any of our exam questions and answers

  • 24/7 customer support, Secure shopping site
  • Free One year updates to match real exam scenarios
  • If you failed your exam after buying our products we will refund the full amount back to you.

Best Preparations of NS0-173 Exam 2021 Cisco and NetApp FlexPod Unlimited 62 Questions [Q16-Q31]

Share

Best Preparations of NS0-173 Exam 2021 Cisco and NetApp FlexPod Unlimited 62 Questions

Focus on NS0-173 All-in-One Exam Guide For Quick Preparation.

NEW QUESTION 16
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)

  • A. a DS4246 with twenty-four 6 TB NL-SAS HDDs
  • B. a two-node FAS8200 with a 4 TB NL-SAS HDD
  • C. a DS224C with twenty-four 3.8 TB SSDs
  • D. a two-node AFF A200 with a 3.8 TB NSE SSD

Answer: B,C

 

NEW QUESTION 17
A customer wants to configure SAN boot for its FlexPod system. The customer must consider the minimum number of FC ports to be configured on each node in the ONTAP storage solution.
In this scenario, what is the minimum number of FC ports that should be configured per storage node?

  • A. three
  • B. two
  • C. four
  • D. one

Answer: A

 

NEW QUESTION 18
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?

  • A. MDS9148>show fcfwd
  • B. MDS9148>show flogi database
  • C. MDS9148>show fcdomain
  • D. MDS9148>show fcc

Answer: B

 

NEW QUESTION 19
A customer is planning to use a pair of MDS switches in a FlexPod design to host a few SAN workloads.
In this scenario, which two features should be enabled on the MDS switches for a successful configuration? (Choose two.)

  • A. NPIV
  • B. port-channel-trunk
  • C. NPV
  • D. fport-channel-trunk

Answer: A,B

 

NEW QUESTION 20
Two data centers are 75km apart. The customer wants to deploy a FlexPod solution in each data center to maintain high availability between the two sites with minimal possible data loss.
In this scenario, which technology would you use at the NetApp storage layer?

  • A. SnapVault
  • B. SnapMirror
  • C. FlexArray
  • D. MetroCluster

Answer: D

 

NEW QUESTION 21
You are configuring a FlexPod system for NAS protocols. You want to ensure that there are multiple paths between the initiators and targets in the solution.
Which two steps will accomplish this task? (Choose two.)

  • A. Disable LACP.
  • B. Configure the VSANs in the Cisco Nexus 5000 switches.
  • C. Configure the VLANs in Cisco UCS Manager as Common/Global.
  • D. Allow the VLANs over the vPC peer link.

Answer: A,C

 

NEW QUESTION 22
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
Which tool satisfies the requirements of this customer's heterogeneous environment?

  • A. NetApp OnCommand Unified Manager
  • B. UCS Central
  • C. UCS Director
  • D. NetApp OnCommand Insight

Answer: C

 

NEW QUESTION 23
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. DualWire Management mode
  • B. Cluster mode
  • C. Direct Connect mode
  • D. SingleConnect mode
  • E. Multipath mode

Answer: A,C,D

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 24
A customer wants to extend a Layer 2 network over a Layer 3 Nexus 9000 infrastructure.
Which Layer 2 overlay scheme accomplishes this task?

  • A. VXLAN
  • B. EIGRP
  • C. STP
  • D. vPC

Answer: A

Explanation:
XLAN tunnels the Layer 2 network over the Layer.

 

NEW QUESTION 25
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?

  • A. 0
  • B. 1
  • C. 2204XP.
  • D. 2208XP

Answer: C

Explanation:
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.

 

NEW QUESTION 26
A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data be replicated to the new location.
Which two software applications accomplish this task? (Choose two.)

  • A. FlexCache
  • B. SnapVault
  • C. SnapRestore
  • D. SnapMirror

Answer: A,D

Explanation:
FlexClone®: Instant virtual copies with file and volume granularity
SnapMirror®: Integrated data replication technology for simple, efficient, flexible disaster recovery and backup use cases

 

NEW QUESTION 27
A customer wants to deploy FlexPod for a VDI solution with 10,000 users, each with 10 GB of storage allocated.
To support this configuration, which three components must be sized? (Choose three.)

  • A. the optical cable length
  • B. the fabric interconnect ports
  • C. the Cisco UCS servers
  • D. the 1GbE ports from user systems
  • E. the NetApp AFF storage

Answer: B,C,D

 

NEW QUESTION 28
A customer is investigating options for implementing a FlexPod Datacenter solution that is using vSphere 6.x.
In this scenario, which two resources would be important to review? (Choose two.)

  • A. Cisco Validated Design documents
  • B. NetApp Technical Report
  • C. Cisco Cloud Center documentation
  • D. VMware vSAN documentation

Answer: A,B

 

NEW QUESTION 29
A client has a FlexPod Datacenter solution with four active fabric links in port channel mode established between the Cisco Fabric Interconnects and the IOMs on a Cisco 5108 blade chassis. The blade chassis is fully populated with Cisco UCS B200M5 blades. A worker in the data center inadvertently unplugs the fourth uplink cable from IOM-A while working in the rack.
In this scenario, what happens to the network traffic?

  • A. Connectivity for servers 3, 4, 7, and 8 all fail over to IOM-B.
  • B. Traffic is load-balanced within IOM-A.
  • C. There is a loss of connectivity for servers 4 and 8.
  • D. Traffic is load-balanced within IOM-B.

Answer: A

 

NEW QUESTION 30
Click the Exhibit button.

You have designed a FlexPod Express solution that uses a NetApp ONTAP controller, Cisco UCS C-Series servers, and Cisco Nexus 3000 Series switches, as shown in the exhibit. Which three storage protocols are supported in this design? (Choose three.)

  • A. FCoE
  • B. SMB
  • C. iSCSI
  • D. FC
  • E. NFS

Answer: C,D,E

 

NEW QUESTION 31
......

Guaranteed Success with NS0-173 Dumps: https://www.braindumpsit.com/NS0-173_real-exam.html