DES-1241 exam is checking the capacities of those professionals who largely perform duties related to PowerStore implementation and support. By passing it, the candidate earns the Specialist – Platform Engineer, PowerStore Version 1 accreditation. Before heading this route, one should offer proof of having been awarded one of the certifications appearing in this list:
- Associate - Information Storage and Management Version 2.0.
- Associate - Information Storage and Management Version 3.0;
- Associate - Information Storage and Management Version 4.0;
NEW QUESTION 52
Refer to the exhibit.
A Storage Administrator noticed a solid amber LED. What does this mean?
- A. Drive rebuilding
- B. Drive faulted
- C. Power up
- D. Drive identification on
Answer: B
NEW QUESTION 53
Which option is used when running the journalctl command to query log messages regardless of capitalization?
- A. option -ignorecase
- B. option -quotes
- C. option --casesensitive=TRUE/FALSE
- D. option --casesensitive=YES/NO
Answer: A
NEW QUESTION 54
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?
- A. An increased fan speed signal is sent to the surviving fans and the system continues normal operations
- B. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down
- C. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
- D. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
Answer: C
NEW QUESTION 55
A Storage Administrator is adding an appliance into an existing Dell EMC PowerStore T cluster.
What is different about the management network configuration for the new appliance compared to configuring an initial appliance for the cluster?
- A. Additional appliance inherits all its management IPs from the existing appliance
- B. All the needed management IP addresses for the new appliance are auto-generated by the cluster
- C. Additional appliance does not require a cluster management IP address
- D. All the needed management IP addresses for the new appliance must be pre-configured on the cluster
Answer: B
NEW QUESTION 56
Refer to the exhibit.
A Storage Administrator noticed a drive LED blinking blue. What does this indicate?
- A. Is faulted
- B. Identification is on
- C. Power up
- D. Access activity
Answer: D
NEW QUESTION 57
What describes the power requirements for Dell EMC PowerStore?
- A. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
- B. T models require less total power than X models
- C. X models require less total power than T models
- D. Lower model numbered systems require less AC line current than higher model numbered systems
Answer: D
Explanation:
Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us
NEW QUESTION 58
What is the protocol used for the storage network?
- A. FC
- B. SMB
- C. iSCSI
- D. NFS
Answer: C
Explanation:
Reference:
https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18149-dell-emc- powerstore-platform-introduction.pdf (23)
NEW QUESTION 59
When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-ntwk-plang_en-us.pdf (22)
NEW QUESTION 60
Which component is hot-swappable?
- A. Fan
- B. BBU
- C. SFP
- D. Expansion IO module
Answer: D
Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-hwg_en-us.pdf (15)
NEW QUESTION 61
Through which network do external hosts connect to the cluster for data access?
- A. ICD
- B. Management
- C. ICM
- D. Storage
Answer: D
Explanation:
Explanation/Reference: https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf
NEW QUESTION 62
Refer to the exhibit.
A Storage Administrator noticed a solid amber LED. What does this mean?
- A. Drive rebuilding
- B. Drive faulted
- C. Power up
- D. Drive identification on
Answer: B
Explanation:
Explanation/Reference: https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and- states-for-troubleshooting?lang=en
NEW QUESTION 63
What does the output of the command "svc_diag list --basic" show?
- A. License status
- B. Failover status
- C. Master_appliance_ID
- D. Boot mode
Answer: C
NEW QUESTION 64
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?
- A. Clear the boot mode
- B. Disable node B boot mode
- C. Reboot node B
- D. Return node A to normal mode
Answer: D
NEW QUESTION 65
From where can a data collection be initiated within Dell EMC PowerStore Manager?
- A. Cluster, appliance, and alerts
- B. Node, storage resource, and alerts
- C. Appliance, node, and storage resource
- D. Cluster, appliance, and event log
Answer: C
NEW QUESTION 66
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?
- A. An increased fan speed signal is sent to the surviving fans and the system continues normal operations
- B. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
- C. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
- D. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down
Answer: D
NEW QUESTION 67
Which option is used when running the journalctl command to query log messages regardless of capitalization?
- A. option -ignorecase
- B. option -quotes
- C. option --casesensitive=TRUE/FALSE
- D. option --casesensitive=YES/NO
Answer: A
Explanation:
Explanation/Reference:
NEW QUESTION 68
A Storage Administrator notices a Major alert present in Dell EMC PowerStore Manager relating to data protection. What action within the alert details slide-out panel is helpful in troubleshooting the data protection problem?
- A. Examine Notifications to obtain a list of corrective actions
- B. Access the Repair Flow link to schedule a support engagement
- C. Acknowledge the alert to clear and resolve the problem
- D. View the Associated Events for earlier related alerts
Answer: B
NEW QUESTION 69
What is a step in configuring the ToR data switches for a Dell EMC PowerStore X?
- A. Create VLANs for NAS servers
- B. Configure a port for the discovery laptop
- C. Configure LACP uplink to management switch
- D. Create node A port-channel
Answer: B
NEW QUESTION 70
What are the recommended number of network switches in a Dell EMC PowerStore T environment?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-plang/ powerstore-t-model-appliance-networks?guid=guid-97a3e988-c1bc-4f51-a445-3af23f19da1b&lang=en-us
NEW QUESTION 71
Which network traffic is encrypted using IPsec?
- A. ICM network
- B. Inter-node network
- C. ICD network
- D. OOB network
Answer: A
NEW QUESTION 72
What is the protocol used for the storage network?
- A. FC
- B. SMB
- C. iSCSI
- D. NFS
Answer: C
Explanation:
Explanation/Reference: https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18149-dell- emc-powerstore-platform-introduction.pdf (23)
NEW QUESTION 73
......
Pass EMC DES-1241 Exam Quickly With BraindumpsIT: https://www.braindumpsit.com/DES-1241_real-exam.html