[Sep-2021] Get 100% Real 500-920 Exam Questions, Accurate & Verified BraindumpsIT Dumps in the Real Exam!
Pass Your Cisco Channel Partner Data Center Exams Fast. All Top 500-920 Exam Questions Are Covered.
NEW QUESTION 13
When server is booting from SAN, which command verifies the PLOGI sessions with the target?
- A. FCMap
- B. Lunmap
- C. Lunlist
- D. FCIist
Answer: C
NEW QUESTION 14
You are in the process of upgrading your UCS M3 Server to a newer UCS M4 Server. You associate the Service Profile to the new UCS Server, but it fails to boot You suspect of a failed boot hard drive. You check your RAID1 Boot LUN in UCS Manager, but see no error messages What could be causing the issue?
- A. A misconfiguration on the Service Profile Local Disk Policy
- B. A misconfiguration on the Service Profile Local Boot Policy
- C. The newer Cisco UCS M4 Server is using flash drives, not hard drives
- D. The newer Cisco UCS M4 Server is using disks of larger capacity than the previous UCS M3 Server
Answer: C
NEW QUESTION 15
What is the result of enabling the Core File Exporter in UCS Manager?
- A. A core dump file will be immediately created and transmitted using HTTP protocol
- B. A core dump must be remotely activated by Cisco TAC.
- C. A core dump will immediately be generated and will be exported
- D. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP
Answer: C
NEW QUESTION 16
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?
- A. The chassis will be recognized and both links will be active
- B. The chassis will be recognized but only one of the links will be active.
- C. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
- D. The chassis will not be recognized
Answer: D
NEW QUESTION 17
A new UCS dual fabric cluster is being configured with a single chassis. The administrator notices that the cluster is not in High Availability (HA) mode. What is the possible cause?
- A. The HA plugin has not been installed in UCS Manager
- B. The UCS-FI-HA license has not been activated in UCS Manager
- C. The links to the chassis are not enabled
- D. No uplinks are active into the data center.
Answer: A
NEW QUESTION 18
When troubleshooting a LAN connectivity issue, you notice a failed uplink from the Cisco UCS Fabric Interconnects to the upstream LAN switch. What two could be causing the issue? (Choose two )
- A. Misconfigured QoS parameters on the failed uplink
- B. A port channel mismatch between the Fabric Interconnects and the upstream LAN switch
- C. A SFP Type mismatch between the Fabric Interconnects and the upstream LAN switch
- D. A port speed configuration mismatch between the Fabric Interconnects and the upstream LAN switch
- E. Misconfigured VLAN on the failed uplink
Answer: A,B
NEW QUESTION 19
When troubleshooting UCS initialization issues that require Fabric Interconnect reboots, which Fabric Interconnect should be rebooted first?
- A. The subordinate Fabric Interconnect
- B. The Cisco UCS Manager will determine with Fabric Interconnect to reboot
- C. The primary Fabric Interconnect
- D. Both Fabric Interconnects must be rebooted simultaneously
Answer: C
NEW QUESTION 20
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?
- A. The server does not have a service profile assigned, but has been discovered by UCS Manager
- B. The server has a service profile assigned, but has connectivity issues with UCS Manager
- C. The server is not properly connected
- D. The server has been properly connected, but has not been discovered by UCS Manager
Answer: C
NEW QUESTION 21
What are three possible causes of service profile association failure due to iSCSI configuration issue? (Choose three )
- A. Inappropriate network configuration
- B. Misconfigured iSCSI parameters
- C. iSCSI Target out of configured range of services
- D. Misconfigured LUN. LUN masking
- E. Wrong WWNN
- F. Improperly assigned iSCSI Class of Service
Answer: A,B,C
NEW QUESTION 22
What is the next step after performing a UCS firmware upgrade, and downloading the latest drivers both for your RAID Controller and your Fibre Channel HBA?
Check the HCL
- A. Test device driver compatibility
- B. No need to do anything Drivers are automatically installed for you
- C. No Drivers are needed in a UCS environment
- D. Apply the device driver update to the devices
Answer: A
NEW QUESTION 23
Which are two benefits of integrating Cisco UCS C-series servers with Cisco UCS Manager? (Choose two ) Cisco UCS Manager provides the ability to automatically update C-series firmware and device drivers from a single global interface.
- A. Cisco UCS Manager uses service profiles and resource pools to allow the deployment of multiple servers with a single common template
- B. Cisco UCS Manager is able to act as a common centralized management platform for both blade and rack servers in a single domain.
- C. Cisco UCS Manager provides the ability to manage C-series in multiple physical domains from a single global interface
- D. Cisco UCS Manager can automatically power on and off servers to scale elastically according to application performance demands
Answer: B
NEW QUESTION 24
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?
- A. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
- B. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
- C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
- D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
Answer: C
NEW QUESTION 25
After installing a new UCS M4 server, which two Cisco Integrated Management Controller connectivity options do you have? (Choose two )
- A. XML API Access
- B. Web Access
- C. In-band Access
- D. Out-of-Band Access
- E. SNMP
Answer: A,C
NEW QUESTION 26
When booting up a Cisco UCS Server you want to see boot time diagnostic messages of the POST, what action is required for you to do so?
- A. Enable Quiet Boot on the Server's BIOS
- B. Disable Fast Boot on the Server's Service Profile
- C. Disable Fast Boot on the Server's BIOS
- D. Restart the Server
- E. Enable Quiet Boot on the Server's Service Profile
Answer: E
NEW QUESTION 27
Which Cisco UCS internal component maintains the UCS XML database, manages the FSM stages and operations and instructs the Application Gateway to perform operations on physical and logical elements?
- A. Cisco UCS Manager
- B. Cisco Application Gateways
- C. Cisco Data Management Engine
- D. Cisco Finite State Machine
Answer: C
Explanation:
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/System-Monitoring/3-1/b_UCSM_GUI_System_Monitoring_Guide_3_1/b_UCSM_GUI_System_Monitoring_Guide_3_1_chapter_0100.html
NEW QUESTION 28
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?
- A. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
- B. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
- C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
- D. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
- E. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
Answer: D
NEW QUESTION 29
......
Penetration testers simulate 500-920 exam: https://www.braindumpsit.com/500-920_real-exam.html